168
5.14.2 Copy PowerScan
®
M8300 Series
Procedure
:
c
Using the slave reader and its BC-80X0 cradle, follow the initialization
procedure in chapter 4 of this manual or from the Quick Reference Guide.
d
With the master PowerScan
®
M8300 (correctly configured reader), read the
Copy Configuration bar code below. Then place it onto an BC-80X0 cradle
within 10 seconds. The reader will beep indicating the configuration has been
copied.
The configuration will be simultaneously sent over the RS-232 interface of the
BC-80X0. If this causes undesired effects disconnect the RS-232 cable
between the PC and BC-80X0 during this process.
Copy Configuration
Ì$+ZZ0$-*Î
e
With the slave PowerScan
®
M8300, read the Get Configuration bar code below.
Then place it onto the same BC-80X0 cradle used in the step above. The slave
reader's address will not be changed.
Get Configuration
Ì$+ZZ2$-4Î
The configuration will be copied from the master to the slave PowerScan
®
M8300.
The slave PowerScan
®
M8300 signals the end of the procedure with a series of
beeps. It is now ready to be used with its own BC-80X0 cradle.
f
Repeat the procedure above to configure other slave readers. The
BC-80X0 can continue to configure slave readers until it receives another
command or data.