Chapter 12: The Ethernet (Wired) Interface
Internal Interface Settings
Psion Teklogix 9160 G2 Wireless Gateway User Manual 141
Table 12.5 Ethernet Settings For Internal LAN
Field Description
MAC Address
Shows the
MAC
address for the Internal interface for the Ethernet port on this access point. This is a read-
only field that you cannot change.
VLAN ID
If you choose to configure Internal and Guest networks by “VLANs”, this field will be
enabled
.
Provide a number between 1 and 4094 for the Internal VLAN.
This will cause the access point to send DHCP requests with the VLAN tag. The switch and the DHCP
server must support
VLAN
IEEE
802.1p
frames. The access point must be able to reach the DHCP
server.
Check with the Administrator regarding the VLAN and DHCP configurations.
Management
VLAN ID
If you have enabled VWNs or Guest access via VLAN, this field will be enabled.
Enter a value for the Management VLAN ID. This ID can be any value between 1 and 4094.
The Management VLAN ID enables you to specify the VLAN used for managing the AP. You can then
manage the AP via the Web User Interface, the Command Line Interface, and SNMP using this VLAN.
If the Connection Type is set to DHCP, this will cause the access point to send DHCP requests with the
VLAN tag. The switch and the DHCP server must support VLAN IEEE 802.1Q frames. The access point
must be able to reach the DHCP server.
There are no restrictions on the Management VLAN ID you specify. The Management VLAN ID can be the
same as the Internal VLAN ID, the Guest VLAN ID, a VWN VLAN ID, or the Untagged VLAN ID.
Untagged VLAN
If you have enabled VWNs or Guest access via VLAN, you can enable or disable untagged VLANs.
Select
Enabled
to enable Untagged VLAN.
Select
Disabled
to disable Untagged VLAN.
If Untagged VLAN is enabled, then any packets received without a VLAN tag will be treated as if they were
received with the specified Untagged VLAN ID.
If Untagged VLAN is disabled, then any packets received without a VLAN tag are bridged to WDS links, but
not otherwise used by the AP.
Untagged VLAN
ID
If you have enabled Untagged VLAN, this field will be enabled.
Enter a value for the Untagged VLAN ID. This can be any value between 1 and 4094.
There are no restrictions on the Untagged VLAN ID you specify. The Untagged VLAN ID can be the same
as the Internal VLAN ID, the Guest VLAN ID, a VWN VLAN ID, or the Management VLAN ID.