Psion Teklogix 7530 G2 Hand-Held Computer User Manual 155
Chapter 5: Configuration
Non-Decoded Scanners
Field Size/Chars
Refer to the description beginning on page 148 for details.
5.11.2.12 MSI Plessey
Enabled
Set this parameter to on to enable “MSI Plessey”.
One Check Digit
If this parameter is enabled, it is assumed that the last digit is a check digit.
Include Check
If this parameter is enabled, the check digit is included with the decoded bar
code data.
Field Size/Chars
Refer to the description beginning on page 148 for details.
5.11.2.13 Discrete 2 of 5
Enabled
Set this parameter to on to enable “Discrete 2 of 5”.
Mod 10 Check
If this parameter is enabled, the Mod 10 check digit is calculated. This calculation is
the same as the Code 39 Mod 10 check digit.
ITF Check
If this parameter is enabled, the ITF-14/16 Mod10 check digit is calculated.
Include Check
If this parameter is enabled, the check digit is included with the decoded bar
code data.
Field Size/Chars
Refer to the description beginning on page 148 for details.